X-ray and Imaging Servicing
Intraoral units, OPGs, CBCTs, sensors and PSP scanners from Dentsply Sirona, Carestream, Dürr Dental and Planmeca, plus the radiation compliance records that go with them.
UNIVERSAL DENTAL SOLUTIONS
Intraoral units, OPGs, CBCTs, sensors and PSP scanners from Dentsply Sirona, Carestream, Dürr Dental and Planmeca, plus the radiation compliance records that go with them.
Done to the manufacturer's maintenance schedule for the unit. For an OPG or CBCT that typically covers mechanical alignment and movement checks, collimation and beam alignment, exposure and timer verification, image quality test using the manufacturer's phantom, calibration where the unit supports it, sensor and detector checks, software and firmware status, cleaning of optical and mechanical paths, and an electrical safety test. For intraoral units: tube head and arm stability, timer and exposure checks, cone and collimation, and electrical safety. You receive the service report plus the records you need for your radiation management plan.
The faults we see most: unit will not expose (interlocks, exposure switch, pre-heat or tube fault), arm drift on intraoral units, OPG motion errors and positioning faults, image quality problems (artefacts, dark or blurred images that are not patient movement), sensor not detected or intermittent (cable, USB, software), and PSP scanner feed and erase faults. Many image quality complaints turn out to be positioning or software rather than hardware; we check both before replacing anything expensive.
Owning dental X-ray apparatus in NSW or the ACT comes with regulatory obligations: apparatus registration, the appropriate licences, a radiation management plan, periodic compliance testing by a consulting radiation expert, and a maintenance record for each unit. The exact requirements and testing intervals are set by the NSW EPA and ACT Health and do change, so check the current rules for your apparatus type or ask us. We look after the equipment side: a dated service and electrical safety report for each unit, logbook entries, and the manufacturer-specified acceptance testing after an installation or relocation. Shielding assessments and formal compliance tests have to be carried out by a consulting radiation expert; we coordinate these with a CRE we work with regularly and have the unit ready so the test goes smoothly.
We install and commission new imaging equipment and relocate existing units, including the acceptance testing the manufacturer specifies, and we coordinate the room shielding assessment with a consulting radiation expert. If you are planning a new imaging room, involve us before the walls go up; shielding is far cheaper to get right at that stage.
We recommend an annual service, in line with most manufacturers' schedules. Separate compliance testing by a consulting radiation expert is required at the interval your state regulator sets for the apparatus type; we can tell you what currently applies to your units.
Sometimes. Just as often it is exposure settings, a calibration that needs redoing after a software update, or a detector that needs cleaning. Send us an example image with your booking and we can often tell you before we arrive.
Usually. Cable damage near the sensor and USB or driver problems account for most cases. A damaged sensor itself is normally a replacement rather than a repair.
Yes, including re-commissioning. We coordinate the shielding assessment for the new room and help with the registration paperwork for the new location.
Prefer one predictable monthly fee? Annual servicing, validation and priority breakdown response are bundled in our Equipment Care Plans.
Call (02) 8313 0559 and talk to a technician, not a call centre. Or send us the details and we will come back to you the same business day.